Clip-loc – Metal Sales Clip-Loc Installation User Manual

Page 47

Advertising
background image

CLIP-LOC

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 2/03

812.246.1935 (Corporate Offi ce) • www.mtlsales.us.com

46

E

AVE

O

VER

O

PEN

F

RAMING

Clip-Loc Fastening Pattern

#12-14 x 1

1

/

2

" SD XL

(6 per panel)

#10-16 x 1" PHD (1'-0" o.c.)

Eave

Double Bead Tape Sealant

Cleat

Clip-Loc Inside Closure

#12-14 x 1

1

/

2

" SD XL (6) per panel (see below)

Clip-Loc Panel

All eave flshings must be installed prior to panel installation.
1. Position and install Cleat to wall with appropriate fastener, 1'-0" o.c. Make sure Cleat allows for proper Eave attachment.
2. Install Eave flashing by sliding open hem onto Cleat and resting the Eave flashing back against substrate. To hold Eave flashing
in place fasten to substrate with #10-16 x 1" Pancake Head Woodscrew 4’-0" o.c.
3. Apply a row of Double Bead Tape Sealant across Eave flashing approximately 2" from face of Eave flashing.
4. Properly align and install Clip-Loc Inside Closures to accommodate Clip-Loc panel rib alignment. Closures must be lined up
with panel ribs for proper seal. Do not apply tape sealant on top of closure.
5. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a bead
of tube sealant between the flashings and securing with pop rivets 2

1

/

2

" o.c.

6. Once panels have been installed, see (pages 44-45), fasten through panel, closure, and sealant into substructure with 6 fasteners
per panel. Fasteners must penetrate closure and sealant to eliminate closure movement.

CAUTION

Additional screws

may be required for

high snow loading

and steep slopes.

1:12 Slope
Minimum

INSTALLATION NOTES

0"-1

1

/

2

"

3

1

/

2

" MIN.

Advertising