Clip-loc – Metal Sales Clip-Loc Installation User Manual

Page 32

Advertising
background image

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 2/03

812.246.1935 (Corporate Offi ce) • www.mtlsales.us.com

31

CLIP-LOC

R

AKE

P

ARAPET

(O

FF

M

ODULE

) O

VER

D

ECKING

Clip-Loc Floating Rake Zee and Clip-Loc panels must be installed prior to rakewall installation (see page 21-22). Panel
must be field bent up 1

5

/

8

".

1. Apply a row of Double Bead Tape Sealant between Floating Rake Zee and field bent panel rib. Fasten field bent panel rib to
Clip-Loc Floating Rake Zee with 12-14 x 1½" SD XL 1'-0" o.c.
2. With Clip-Loc panel properly fastened to Clip-Loc Floating Rake Zee, apply a row of Double Bead Tape Sealant across top of
Floating Rake Zee.
3. Install Clip-Loc Rakewall flashing on top of Floating Rake Zee. Fasten through Clip-Loc Rakewall, sealant, and into Clip-Loc
Floating Rake Zee with ¼-14 x

7

/

8

" Stitch XL 1'-0" o.c. Stagger Stitch fastener so that there is no interference with 12-14 1½"

SD XL already installed.
4.Install Counter Flashing,Reglet,or wall panel and fasten to parapet wall with appropriate fastener 1'-0" o.c. If Counter Flashing
or Reglet is used seal to parapet wall with tube sealant. Do NOT fasten Clip-Loc Rakewall to wall.
5. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a bead
of tube sealant between the flashings and securing with pop rivets 2

1

/

2

" o.c.

Double Bead Tape Sealant

#

1

/

4

-14 x

7

/

8

" Stitch XL (1'-0" o.c.)

Clip-Loc Panel

Moisture Barrier (by others)

Floating Rake Zee

Clip-Loc Rakewall

12-14 x 1

1

/

4

" Shoulder Tech (1'-0" o.c.)

12-14 x 1

1

/

2

" SD XL (1'-0" o.c.)

1:12 Slope
Minimum

INSTALLATION NOTES

Field bend panel rib up 1

5

/

8

"

Advertising