Clip-loc – Metal Sales Clip-Loc Installation User Manual
Page 33
CLIP-LOC
© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 2/03
812.246.1935 (Corporate Offi ce) • www.mtlsales.us.com
32
H
IP
O
VER
D
ECKING
1. Once panels have been installed, slide Clip-Loc Turn-up Tool over end of panel and bend pan up until flush with top of panel
rib. Turn up all Clip-Loc pans on both sides of hip (see page 19).
2. Apply a row of Double Bead Tape Sealant across panel, up and over all ribs approximately 2"-4" from panel end on both sides
of
hip.
3. Install a Clip-Loc Outside Hip Closure over tape sealant. Before continuing make sure closure placement will accommodate
20" Hip flashing. Set closure in tape sealant.
4. Once all closures have been installed, place a row of Double Bead Tape Sealant across the top of closures on both sides of hip.
5. Install 20" Hip flashing and secure to Clip-Loc panel rib with a ¼-14 x
7
/
8
" Stitch XL at every rib.
6. If two or more flashings are required, lap the flashing over the previously installed flashing by a minimum of 2" placing a bead
of tube sealant between the flashings and securing with pop rivets 2
1
/
2
" o.c.
1:12 Slope
Minimum
Double Bead Tape Sealant
#
1
/
4
-14 x
7
/
8
" Stitch XL (each rib)
Clip-Loc Panel
Moisture Barrier (by others)
Clip-Loc Clip
20" Hip Cover
Double Bead Tape Sealant
Clip-Loc Outside Hip Closure
2" MAX.
C
L
INSTALLATION NOTES
Clip-Loc panel must be anchored to solid deck behind outside closure at all ridge, hip, endwall, and peak
conditions to fi x the panel when using this fl oating eave detail.