MTS Multipurpose Elite Test User Manual
Page 42
Advertising
![background image](/manuals/568042/42/background.png)
Note:
Some of the property values you need to enter for this sample test may already be present as default
values.
1. Click on the Procedure tab, and scroll to the Ramp activity in the Toolbox list.
2. Drag and drop the Ramp activity on the “Drop Activities Here” text in the work area.
Adding a Ramp Activity
3. Define Ramp activity properties:
a. Enter the following values as necessary:
Ramp Activity Properties
Value
Property
Ramp to Mean
Display Name
Time
Timing Type
2 sec
Time
Ramp
Ramp Shape
No Compensator
Compensator
Ch 1
Channel List
Displacement
Control Mode
4 mm
Absolute End Level