Effect/Explanation
Value
Property
100%
Frequency
Multiplier
Arbitrary end level control is available
for the Profile activity. For more
No Compensator
Compensator
information about ALC see
on page 84.
Channels 1 and 2 are shown. Channel
1 has a control mode of Displacement,
Ch 1 and Ch 2
Channels
a Level Reference of 0 mm, and a
Level Multiplier of 100%. Channel 2
is not used.
The action names in this column
(<Turn on light>, <Turn off light>) exist
in the profile as keywords.
Profile Action
column label
The actions in this column (Turn on
light, Turn off light) exist in the station
Test Action
column label
configuration as user-defined actions.
You created these actions for the
sample test in
Resource Actions that Map to the
Profile
on page 76. The MPE
application automatically maps actions
in the station to matching action
names in the profile.
Causes the “Turn on light” action in
the station to execute when the <Turn
Turn on light
<Turn on
light>
on light> action in the profile plays out.
The “Turn on light” action in the
station sets (turns on) the Digital
Output 1 resource.
Causes the “Turn off light” action in
the station to execute when the <Turn
Turn off light
<Turn off
light>
off light> action in the profile plays out.
The “Turn off light” action in the
station clears (turns off) the Digital
Output 1 resource.
The counter name in this column
(Pass Counter) exists in the profile as
a keyword.
Profile
Counter
column label
This column lists counters you create
with MPE using variables. This
Variable
column label
Multipurpose Elite Test Design Guide 79