Specifications
Table 1: SDM-2009 Specifications
Input Power
12 VDC
NOTE: AC Adapter with 100 - 240 VAC, 50/60 Hz,
0.6A input and 12 VDC, 1.2A output provided as
standard.
Environmental Conditions
• For Indoor Use Only
• -10° C to 40° C, below 80% Relative Humidity, Non-
Condensing
Applicable Instrument
GX-2009
Memory Capacity
64 KB (Standalone configuration only)
Maximum Record Size
256 bytes (Standalone configuration only)
Maximum Number of
Records Saved
200 (Standalone configuration only)
Number of Calibration Gas
Cylinders
One calibration gas cylinder per bump test or
calibration
Standard Accessories
•
AC Adapter
•
USB Flash Drive
•
Single Module Data Viewer Program
•
SDM-GX Docking Station PC Controller
Program
•
Inlet Air Filter
•
Instruction Manual
•
10 Foot Long 5/16 Inch Exhaust Tube
•
One 3 Foot Long 3/16 Inch Tube for GAS
Fitting
•
10 Foot Long 3/16 Inch Tube for GAS Fitting
Manifolding
•
2 T-Fittings
•
Check Valve
•
USB Cable, Type A to Type B