Stacking panel, Remove components – Rockwell Automation PF700 PowerFlex 700 Drive Components Replacement - Frame 9 User Manual

Page 25

Advertising
background image

Rockwell Automation Publication 20B-IN025B-EN-P - January 2011

25

Basic Component Removal Procedures Chapter 2

Stacking Panel

See

Chapter 1 - Drive Components

to locate the component detailed in these

instructions.

Remove Components

1.

Read and follow the

Safety Precautions on page 8

and

Important Initial

Steps on page 10

.

2.

All wiring and terminals attached to the Stacking Panel are shown below.
Label any unidentified wiring and terminals before disconnecting.

IMPORTANT

The figure below is shown with the Blower Control Panel removed for
visual clarity. However, you don’t need to remove the Blower Control
Panel to remove the Stacking Panel.

TIP

This step may be performed more easily if you first remove the
Communications Panel following the instructions on

page 22

.

Connected Component

Label on Wire
or Connector

Label on Board

Notes

Precharge Board

J1, J2

J1, J2

TB2

TB2

For DC input only.

DC Bus Filter Board

TB2

Thermal Sensor Wire

J8

J18

J23

J6

Shown with Main Control Panel, Blower Control Panel and Safety Shield Removed

J14…J16

J1

J2

TB2

TB2

Precharge

Board

(DC input

shown)

DC Bus

Filter Board

Power Interface Board

Thermal Sensor

Wire

Advertising
This manual is related to the following products: