Dc bus filter board, Remove components, Install components – Rockwell Automation PF700 PowerFlex 700 Drive Components Replacement - Frame 9 User Manual

Page 48

Advertising
background image

48

Rockwell Automation Publication 20B-IN025B-EN-P - January 2011

Chapter 3 Component Replacement Procedures

DC Bus Filter Board

See

Chapter 1 - Drive Components

to locate the component detailed in these

instructions.

Remove Components

1.

Read and follow the

Safety Precautions on page 8

and

Important Initial

Steps on page 10

.

2.

Remove the safety shield over the DC Bus Filter Board.

3.

Disconnect all wiring from TB1 and TB2 terminals.

4.

Remove the four board mounting bolts.

5.

Remove the DC Bus Filter Board; return or dispose of it properly.

Install Components

1.

Install the new DC Bus Filter Board. Torque mounting bolts to 1.7 N•m
(15 lb•in).

2.

Reconnect all wiring as detailed in the above Table.

3.

Replace all safety shields and enclosure covers before applying power to the
drive.

TB2

TB1

TB2-3

TB2-1

TB1-3

TB1-1

Board Mounting Bolts (4)

Connector

Wire Color(s)

Connects To:

TB1-1

Black

J24 on Power Interface Board

TB1-3

Red

J24 on Power Interface Board

TB2-1

Black

DC- Bus Capacitor

TB2-3

Red

DC+ Bus Capacitor

Advertising