Precharge board, Remove components – Rockwell Automation PF700 PowerFlex 700 Drive Components Replacement - Frame 9 User Manual

Page 46

Advertising
background image

46

Rockwell Automation Publication 20B-IN025B-EN-P - January 2011

Chapter 3 Component Replacement Procedures

Precharge Board

See

Chapter 1 - Drive Components

to locate the component detailed in these

instructions.

Remove Components

1.

Read and follow the

Safety Precautions on page 8

and

Important Initial

Steps on page 10

.

2.

Perform

Remove Blower Control Panel on page 24

.

3.

For DC input: Label customer wiring to TB2 and then disconnect TB2.

4.

Disconnect the all wiring from the Precharge Board.

Note:

Label unidentified connectors to simplify reinstallation.

Connector

Wire Color(s)

Connects To:

AC Input

J1

Red/Black

J24 (+BUS IN) on Power Interface Board

J2

Red/White

Converter SCR Modules (R, S, T)

J3

Red/White

Converter SCR Modules (R, S, T)

DC Input

J1

Red/White

Precharge SCR Module

J2

Blue

Precharge +DC In Busbar

Red

Precharge +DC Out Busbar

Black

DC- Bus Capacitor

J3

Red/White

J10 on Power Interface Board

TB1

Open

TB2

Blue

+DC In Busbar

Red

+DC Out Busbar

Advertising
This manual is related to the following products: