3-2 Use Data Highway 485 Network

Link Design

When you design your DH-485 link, you should use good design practices,
including laying out the link before installation. We also recommend you
consider the following when designing your DH-485 link:

• All performance requirements
• Maintenance
• Possible future changes to the link

Use a Belden 9842 or a Belden 3106A cable to connect your module to
DH-485. Only connect a DH-485 network using a daisy-chain configuration.
If you need to know how to install a DH-485 network, refer to publication
1747-UM011, SLC 500 Modular Hardware Style User Manual.

Two Methods of
Communication Over a
DH-485 Network

The 1756-DH485 module acts as a bridge for two methods of communication.
These methods are:

• DH-485 Messaging
• Common Industrial Protocol (CIP) Messaging

The table Types of Communication on the 1756-DH485 Module lists the
devices that support each communication method.

Types of Communication on the 1756-DH485 Module

Type of Communication

Devices and Software Support

DH-485 messaging

SLC-500 -5/05, 5/04, 5/03, 5/02, 5/01, MicroLogix

Logix controllers

RSLinx and RSLogix 500 software

Common Industrial Protocol
(CIP) messaging

Logix controllers

RSLogix 5000 and RSLinx software