Miscellaneous bits, Data blocks – Rockwell Automation 1771-TCM,D17716.5.108 TEMPERATURE CONTROL MOD User Manual

Page 97

Advertising
background image

Appendix C
Example Ladder Logic Program

C-5

Word B26:0 is used by the program file 2 to set the needed
download-required bits on power-up of the processor or when the
processor is switched from program mode to run mode. If a configuration
block-transfer is required while the processor is in the run mode, it requires
additional ladder logic to be added to latch the appropriate
download-required bit. The program will automatically unlatch the
download-required bit after the successful block-transfer. Configuration
blocks can also be downloaded by setting the download-required bit in the
table from programming terminal.

Important: The ladder logic constantly checks the dynamic block for
changes and will automatically send it out if a change is made in the
dynamic block.

Miscellaneous Bits

File

Word Bit

Description

B21

3

15

Copy configuration blocks

Data Blocks

File

Words

Description

B30

1-23

LoopĆ1 configuration block

B31

1-23

LoopĆ2 configuration block

B32

1-23

LoopĆ3 configuration block

B33

1-23

LoopĆ4 configuration block

B34

1-23

LoopĆ5 configuration block

B35

1-23

LoopĆ6 configuration block

B36

1-23

LoopĆ7 configuration block

B37

1-23

LoopĆ8 configuration block

B38

1-57

Gains block

B39

1-34

Dynamic block

B40

1-64

System status block

Advertising