Chapter 2

Install the Linking Device

Set the DeviceNet Node Address and Data Rate by Using RSNetWorx
for DeviceNet Software

See

Set the DeviceNet Node Address and Data Rate on page 20

for information

about using RSNetWorx software to set node address and data rate.

Set the Linking Device
IP Address

Four methods can be used to set the linking device IP address:

Use the IP address rotary switches on the side of the linking device
Use the DHCP protocol
Use RSLinx Software
Use the web pages of the linking device

Set the Linking Device IP Address by Using the Rotary Switches

The rotary switches are on the right side of the linking device.

Set the IP address according to the table below.

1

250 kbps

2

500 kbps

Other value

Data rate selected via RSNetWorx
software

Switch

Data Rate

Switch

IP Address

000

Administrative mode
The linking device uses the IP address that was used last startup
The web pages are available

001 - 254

192.168.1.XYZ where XYZ is the value of the three switches

888

Reset the linking device to initial out-of-box settings

Other value

The linking device starts in operating mode, using the latest configured IP
address

x100

x10

x1