Ip configuration flowchart – Rockwell Automation 1788-EN2DNR EtherNet/IP to DeviceNet Linking Device User Manual User Manual

Page 14

Advertising
background image

14

Rockwell Automation Publication 1788-UM059A-EN-P - August 2014

Chapter 2

Install the Linking Device

The following figure shows a flowchart describing how the IP configuration is
determined when the linking device is powered up.

IP Configuration Flowchart

TIP

You can enable these values by using the linking device’s IP Configuration web
page. Refer to

Set the Linking Device IP Address by Using the Linking Device

Web Pages on page 16

.

Start

Rotary

Switches = 888?

No

Yes

Factory Reset to DHCP

LED Indication

Rotary

Switches = 000?

Admin Mode

Operational Mode

No

Rotary

Switches

1 - 254?

Yes

No

Yes

Fetch Stored Settings

IP Address:

192.168.1.X

DHCP

Enabled?

Fetch IP Address

from Server

IP Address:

Static Setting

Yes

No

Start up