12

Chapter

12 -1

Call Routines 0 – 68

Calls 0 – 68 are described here. Calls 69 – 127 are described in Chapter
13. Chapter 7 gives you an overview of how to use these calls within your
BASIC program. Use these calls within your BASIC program or from the
command line.

Important: CALL numbers above 127 are not valid and cause the BASIC
module error–

ERROR CALL ARGUMENT OUT OF RANGE.

CALL

Description

Page

CALL

Description

Page

0

reset module

12 -2

35

retrieve numeric input character from PRT2 port

12 -34

1

no operation

12 -2

36

get number of characters in PRT2 port buffers

12 -35

2

timed-block-transfer-read buffer

12 -2

37

clear PRT2 port buffers

12 -35

3

timed-block-transfer-write buffer

12 -3

38

expanded ONERR restart

12 -36

4

set block-transfer-write length

12 -4

39

3.3-Digit Signed, BCD to BASIC Floating Point

12 -38

5

set block-transfer-read length

12 -4

40

set wall clock time

12 -39

6

block-transfer-write buffer

12 -5

41

set wall clock date

12 -40

7

block-transfer-read buffer

12 -5

42

set wall clock day of week

12 -40

8

disable interrupts (no operation)

12 -6

43

date/time retrieve string

12 -41

9

enable interrupts (no operation)

12 -6

44

date retrieve numeric

12 -41

10

3-digit decimal BCD to BASIC floating point

12 -6

45

time retrieve string

12 -42

11

16-bit binary to BASIC floating point

12 -7

46

time retrieve numeric

12 -42

12

4-digit octal to BASIC floating point

12 -7

47

retrieve day of week string

12 -43

13

6-digit decimal BCD to BASIC floating point

12 -8

48

retrieve day of week numeric

12 -43

14

SLC 16-bit signed integer to BASIC floating point

12 -8

49

read remote DH-485 SLC data file

12 -44

15

SLC 16-bit unsigned integer to BASIC floating point

12 -9

50

write to remote DH-485 SLC data file

12 -50

16

enable/disable DF1 packet interrupt

12 -10

51

undefined

12 -58

17

4-digit BCD to BASIC floating point

12 -11

52

date retrieve string

12 -58

18

re-enable control C break function

12 -11

53

undefined

12 -58

19

disable the control C break function

12 -12

54

undefined

12 -58

20

BASIC floating point to 3-digit decimal BCD

12 -12

55

undefined

12 -58

21

BASIC floating point to 16-bit binary

12 -13

56

undefined

12 -58

22

BASIC floating point to 4-digit octal

12 -13

57

undefined

12 -58

23

BASIC floating point to 6-digit decimal BCD

12 -14

58

undefined

12 -58

24

BASIC floating point to SLC 16-bit signed integer

12 -15

59

undefined

12 -58

25

BASIC floating point to SLC 16-bit binary

12 -16

60

string repeat

12 -59

26

BASIC floating point to 3.3-digit BCD

12 -17

61

string append

12 -60

27

BASIC floating point to 4-digit BCD

12 -17

62

number to string conversion

12 -61

28

undefined

12 -18

63

string to number conversion

12 -62

29

read/write to PLC/SLC from module internal string

12 -18

64

find a string in a string

12 -63

30

PRT2 port support parameter set

12 -20

65

replace a string in a string

12 -64

31

display PRT2 port parameters

12 -21

66

insert a string in a string

12 -65

32

enable/disable processor interrupt

12 -22

67

delete a string from a string

12 -66

33

transfer data from PRT1/PRT2 to BTR buffer

12 -23

68

determine length of a string

12 -67

34

transfer data from BTW buffer to PRT1/PRT2

12 -29

what’s next?

12 -67

What’s in This Chapter?