There are 128 BASIC calls. Calls 69 – 127 are described here.
Calls 0 – 68 are described in Chapter 12. Chapter 7 gives you an overview
of how to use these calls within your BASIC program. Use these calls
within your BASIC program or from the command line.

Important: CALL numbers above 127 are not valid and cause the BASIC
module error–

ERROR CALL ARGUMENT OUT OF RANGE.

CALL

Description

Page

CALL

Description

Page

69

undefined

13 -2

99

reset print head pointer

13 -34

70

ROM to RAM program transfer

13 -2

100

download/program assembly language to EEPROM

13 -35

71

ROM/RAM to ROM program transfer

13 -3

101

upload user (E)EPROM code to host

13 -35

72

RAM/ROM return

13 -4

102

undefined

13 -35

73

battery-backed RAM disable

13 -5

103

print PRT1 transmit buffer and pointer

13 -36

74

battery-backed RAM enable

13 -5

104

print PRT1 receive buffer and pointer

13 -37

75

undefined

13 -5

105

reset PRT1 to default settings

13 -37

76

undefined

13 -5

106

undefined

13 -38

77

protected variable storage

13 -6

107

undefined

13 -38

78

set program port communication rate

13 -8

108

enable DF1 driver communications

13 -38

79

set active LED blinking state (no operation)

13 -8

109

print the argument stack

13 -44

80

check battery condition

13 -9

110

print the PRT2 port transmit buffer and pointer

13 -45

81

user PROM check and description

13 -10

111

print the PRT2 receive buffer and pointer

13 -46

82

check user memory module map

13 -11

112

user LED control

13 -47

83

display DH485 port setup

13 -11

113

disable DF1 driver communications

13 -47

84

transfer DH-485 CIF to BASIC input buffer

13 -12

114

transmit DF1 packet

13 -48

85

transfer BASIC output buffer to DH-485 CIF file

13 -13

115

check DF1 status

13 -49

86

check DH-485 interface remote write status

13 -14

116

call user defined assembly language routine

13 -50

87

check DH-485 interface file remote read status

13 -15

117

get DF1 packet length

13 -51

88

BASIC floating point to PLC-5 floating point

13 -16

118

PLC/SLC unsolicited writes

13 -52

89

PLC-5 floating point to BASIC floating point

13 -17

119

reset PRT2 port to default settings

13 -56

90

read remote DH-485 data file to BASIC input buffer

13 -18

120

clear BASIC module I/O buffers

13 -57

91

write BASIC output buffer to remote DH-485 data file 13 -22

121

undefined

13 -57

92

read remote DH-485 CIF to BASIC input buffer

13 -26

122

read remote DF1 PLC data file

13 -58

93

write output buffer to remote DH-485 CIF file

13 -29

123

write to remote DF1 PLC data file

13 -66

94

display current PRT1 port setup

13 -32

124

undefined

13 -74

95

get number of characters in PRT1 buffers

13 -32

125

undefined

13 -74

96

clear PRT1 receive/transmit buffers

13 -33

126

undefined

13 -74

97

enable PRT2 DTR signal

13 -33

127

undefined

13 -74

98

disable PRT2 DTR signal

13 -34