This error message:
Occurs when:
INVALID BAUD RATE
ENTERED
a communication rate other than 300, 600, 1200, 2400, 4800, 9600 or 19200
bit/s is PUSHed using CALL 78
INCOMPLETE ROM
PROGRAM FOUND
CALL 81 detects an incomplete program in the memory module. You can burn
no additional programs onto this EEPROM. All earlier programs are still
accessible
NO PROGRAM
FOUND BUT THE
PROM IS NOT
BLANK
miscellaneous data is found on a “blank” PROM using CALL 81. You should
clear the PROM before using it.