Chapter
Call Routines 69–127

13

13 -59

2.

The BASIC module issues the appropriate READ command to the
remote PLC. The data and status are received from the PLC
processor.

Remote PLC Processor

DATA FILE

BASIC Module

READ command

PRT2

Data and Status

DF1 Network

3.

When data is available, the BASIC module transfers the data into the
BTR buffer and the BASIC module places the transaction status in
the lower byte of BTR buffer word 1. The upper byte of BTR word 1
is reserved.

BASIC Module

Data 2–64

BTR Buffer

Status 1

Reserved

4.

The BASIC module sets the input image table, bit 12 and performs a
block transfer read.

PLC Processor

BASIC Module

PLC Backplane

Sets Input
Image Table
Bit 12