These calls are new to the Series B, BASIC module:

Statement

Page

CALL 0

reset the module

12 -2

CALL 14

SLC 16-bit signed integer to BASIC floating point

12 -8

CALL 15

SLC 16-bit unsigned integer to BASIC floating point

12 -9

CALL 16

enable/disable DF1 packet interrupt

12 -10

CALL 18

re-enable control C break function

12 -11

CALL 19

disable the control C break function

12 -12

CALL 24

BASIC floating point to SLC 16-bit signed integer

12 -15

CALL 25

BASIC floating point to SLC 16-bit binary

12 -16

CALL 29

read/write to PLC/SLC from module internal string

12 -18

CALL 49

read remote DH-485 SLC data file

12 -44

CALL 50

write to remote DH-485 SLC data file

12 -50

CALL 83

display DH485 port setup

13 -11

CALL 84

transfer DH-485 CIF to BASIC input buffer

13 -12

CALL 85

transfer BASIC output buffer to DH-485 CIF file

13 -13

CALL 86

check DH-485 interface remote write status

13 -14

CALL 87

check DH-485 interface file remote read status

13 -15

CALL 88

BASIC floating point to PLC-5 floating point

13 -16

CALL 89

PLC-5 floating point to BASIC floating point

13 -17

CALL 90

read remote DH-485 data file to BASIC input buffer

13 -18

CALL 91

write BASIC output buffer to remote DH-485 data file 13 -22

CALL 92

read remote DH-485 CIF to BASIC input buffer

13 -26

CALL 93

write output buffer to remote DH-485 CIF file

13 -29

CALL 94

display current PRT1 port setup

13 -32

CALL 95

get number of characters in PRT1 buffers

13 -32

CALL 96

clear PRT1 input/output buffers

13 -33

CALL 97

enable PRT2 DTR

13 -33

CALL 98

disable PRT2 DTR

13 -34

CALL 100

download/program assembly language to EEPROM

13 -35

CALL 101

upload user (E)EPROM code to host

13 -35

CALL 103

print PRT1 output buffer and pointer

13 -36

CALL 104

print PRT1 input buffer and pointer

13 -37

CALL 105

reset PRT1 to default settings

13 -37

CALL 108

enable DF1 driver communications

13 -38

CALL 112

user LED control

13 -47

CALL 113

disable DF1 driver communications

13 -47

CALL 114

transmit DF1 packet

13 -48

CALL 115

check DF1 status

13 -49

CALL 116

call user defined assembly language routine

13 -50

CALL 117

get DF1 packet length

13 -51

CALL 118

PLC/SLC unsolicited writes

13 -52

CALL 120

clear BASIC module input and output buffers

13 -57

CALL 122

read remote DF1 PLC data file

13 -58

CALL 123

write to remote DF1 PLC data file

13 -66