Rockwell Automation 2708-DH5B2L_DH5B4L Attended Workstation User Manual

Page 29

Advertising
background image

Chapter 2

Installing a Network

2–16

As soon as the modems establish communication between themselves, the
remote system will be ready for use.

Extension of a network across telephone lines consists of placing a modem
on one side of the line to connect with the Concentrator, and placing another
modem on the other side to connect with the Submaster.

Figure 2.13
Extending Network Across Common Carrier

Indicates RS-232 connect
Indicates telephone line
Indicates RS-485 backbone

W

|

M

|

W

|

W

|

C

|

W

|

W

W

Workstation

S

Submaster

C

Concentrator

M

Master

W

|

W

|

W

|

S

|

W

Key:

Backbone

Network

Tributary
Network

HOST

modem

modem

Telco

Figure 2.14
Use of the Gateway Option

Indicates RS-232 connect
Indicates telephone line
Indicates RS-485 backbone

W

|

W

|

G

|

W

|

W

W

Workstation

S

Submaster

C

Concentrator

M

Master

G

Gateway

W

|

S

|

W

Key:

Backbone

Network

Tributary
Network

modem

modem

Telco

Advertising