6 - operating procedures, Chapter objectives, Operating procedures – Rockwell Automation 2708-DH5B2L_DH5B4L Attended Workstation User Manual

Page 64

Advertising
background image

A–B

6

Chapter

6–1

Operating Procedures

This chapter describes most of the operations normally used in the set-up and
maintenance of a network. It also includes descriptions of some methods
used in discerning correct operation. Some of these are:

verifying proper operation

removal of a Master or Submaster from the network

changing a workstation into a Master

removal of a Normal workstation from the network

adding a Normal workstation to the network

Default Configuration – The major factory default settings are:

Parameter

Value

Configuration Menu

Terminal Number:

0

Network

. . .

. . . . . . . . . . . . . . . . . .

Host Port:

COM

Network

. . . . . . . . . .

. . . . . . . . . . . . . .

Terminal Type:

Normal

Network

. . . . . .

. . . . . . . . . . . .

Lower Poll Address

1

Network

. .

. . . . . . . . . . . . . . . . . .

Upper Poll Address

99

Network

. .

. . . . . . . . . . . . . . . . .

Offline Cycle

40

Network

. . . . . . .

. . . . . . . . . . . . . . . . .

Max Net Retries

10

Network

. . . . .

. . . . . . . . . . . . . . . . .

Comm Port Mode:

Polled

Network

. . .

. . . . . . . . . . . . .

Comm Baud Rate:

9600

Comm Port

. . .

. . . . . . . . . . . . . . .

Comm Data Bits:

7

Comm Port

. . . .

. . . . . . . . . . . . . . . . . .

Comm Parity:

Even

Comm Port

. . . . . .

. . . . . . . . . . . . . .

Comm Stop Bits:

One

Comm Port

. . . .

. . . . . . . . . . . . . . .

Comm CRLF:

Disabled

Comm Port

. . . . . .

. . . . . . . . . . .

Comm Echo:

Disabled

Comm Port

. . . . . . .

. . . . . . . . . . .

Sync Count:

0 (Remains 0 always)

Comm Port

. . . . . . . .

.

Aux Baud Rate:

9600

Comm Port

. . . . .

. . . . . . . . . . . . . . .

Aux Parity:

Even

Comm Port

. . . . . . . .

. . . . . . . . . . . . . .

Aux CRLF:

Disabled

Comm Port

. . . . . . . .

. . . . . . . . . . .

Aux Echo:

Disabled

Comm Port

. . . . . . . . .

. . . . . . . . . . .

Comm Menu Char.:

None

Comm Port

. .

. . . . . . . . . . . . . .

Menu Password

0

System

. . . . .

. . . . . . . . . . . . . . . . . .

Clock Mode

7

System

. . . . . . . .

. . . . . . . . . . . . . . . . . .

File Block Size

256

System

. . . . . .

. . . . . . . . . . . . . . . .

Bar Code Symbology

Code 3 of 9 Enabled

Bar Code

. .

. . .

all others Disabled

The workstation will be reset to these settings when Option H – Reset to
Factory Defaults is selected from the Diagnostics Menu (Menu 6)