Program load status (status display 7) – Rockwell Automation 2708-DH5B2L_DH5B4L Attended Workstation User Manual

Page 39

Advertising
background image

Chapter 4

Status Displays

4–9

This display shows the progress of the loading operation of the A-B VBASIC
program on the top line and the date/time of the loading operation on the
lower line.

Figure 4.9
Program Load Status, Display 7

LOAD STATUS

MSG

AT

hhmmss

yymmdd

Program Load Messages that could appear on the top line are:

Never loaded

This message appears from the time the workstation
is set to factory defaults until the arrival of a
program record.

Loading Line: xx

This message is shown as each program record is
received. It should take only a few moments at most
to load a program. If this line is not being updated
every few seconds, the download operation has been
interrupted, possibly by a communications protocol
error from the Host computer.

Loaded <filename>

This message indicates that the A-B VBASIC
program was loaded without error and started. The
PC program name is shown. Note: This does not
imply that the program loaded is currently running.
For workstation run status, check status display
eight.

Load Sequence xx –

This message indicates that at least one of the
records of the program was received in the wrong
order. The ‘xx’ indicates the expected record.

Length Counters! –

This message indicates that the counters holding the
size of the program’s pseudo-code and array
descriptions do not equal the total program length
counter.

Load Length! –

This message says the amount of pseudo-code
received does not equal the number supplied in the
total length count.

Program Checksum – This message says the checksum of the pseudo-code

does not equal the value expected.

Program Load Status
(Status Display 7)

Advertising