> > A – Abort Currently Running A-B VBASIC Program

Terminates the program which is currently running on the workstation. This
will also generate an error message back to the Host which says: “BASIC
Error: Operator Abort xxxx: yymmddhhmmss”, where xxxx is the address at
which the program was aborted.

> > G – Restart an Aborted BASIC Program

A program which has been aborted using the > > A network directive can be
restarted with this command. The program is restarted at the beginning, and
all variables can be assumed to be re-initialized.

> A – Abort Test

Allows the Host program to terminate the network performance test initiated
by the B command (described next).

> C – Send Text Out Comm Port

Causes the text which follows the command to be sent out the
communications port of the destination workstation. If the symbol “&”
appears first in the text, no carriage return will be output.

Note: Control codes cannot be directly sent, only printable characters.
However, a backslash ( \ ) is converted to a carriage return, a grave accent
( ’ ) is converted into an escape, and an up arrow ( ^ ) is converted into a
linefeed.

Directive: > C text
Action: text specified is sent out comm port of destination workstation.

> c – Send Text Out Aux Comm Port

Same as > C except it uses the aux comm port.

> D – Display Text on Front Panel

Causes the specified text to appear on the front panel displayof the indicated
workstation. If the symbol “&” is the first character of the text, the display is
not cleared prior to displaying the text.

Directive: > D text
Action: text specified is displayed on front panel of workstation.

Note: Control codes cannot be directly sent, only printable characters;
however a grave accent (’) is converted into an ESC.