Network directives (cont’d) – Rockwell Automation 2708-DH5B2L_DH5B4L Attended Workstation User Manual

Page 84

Advertising
background image

Chapter 8

Host Communications

8–9

> T – Set Time

Causes the time and date in the destination workstation to be set to the value
provided as a parameter.

Directive: > T hhmmssnnyymmddw

Where:

hh

= hours

mm

= minutes

ss

= seconds

nn

= 1/100 second

yy

= year

mm

= month

dd

= day #

w

= dayof week

Action: resets time and date in the destination workstation. The entire string

is mandatory. You cannot, for example, set only the time and leave
the date portion off, or the workstation’s date will be set to zeros.
The “w” (day of the week: Sunday – 1) parameter is, however,
optional: if ommited or specified in error, the workstation will
calculate and set its own day of the week.

> Z – Zero Reset Error

Used to zero the reset error and powerfail counters on the designated
workstation. Intended for internal use only.

Directive: > Z
Action: resets the error and powerfail counters

Network Directives (cont’d)