Chapter 4

Status Displays

4–7

C

Count Of Records Lost From Host – This count is incremented
whenever a data record arrives from the network, before the
previous one was read by the A-B VBASIC program.

The lower line contains:

H

Host Output Blocked Flag.

Data collected by the application is not being forwarded to the
network, because the Host device is not currently OPEN by an A-B
VBASIC program. Unless some action is taken to OPEN “Host”,
this data will be stranded. The condition can be cleared by an:

OPEN “Host”
KILL “Host”
KILL “QUE”

L

Lost Data Flag

Data has been lost. This could be because the Host sent a record
and the workstation was not ready to receive it, or the Host is
sending faster than the workstation can process the data.

RC

Record Count From Network – This is a count of the records which
have been transmitted to the Host from the A-B VBASIC program.

S

Size Of Host Queue – This is the number of bytes currently in the
que for transmission to the Host. Data in this queue can be
prevented from going to the Host by:

1. A Host computer which has stopped polling (when the Master is in polled

mode).

2. A Host computer which has issued a XOFF, (any mode).

3. The device Host being closed. This condition is associated with the Host

Output Blocked Flag.

4. The workstation being offline.

Network Que Status