Chapter 8

Host Communications

8–5

The directives which begin with a right angle bracket > direct the
workstation to perform a specific action. Note that any data which is sent
along with the command must be preceded by a space.

> > A

abort the currently running BASIC program

> > G

restart an aborted program

> A

abort the test invoked by B directive

> C

output text to communications port

> c

output text to aux communications port

> D

output test to unit display

> E

erase the current menu password

> F

reset the unit to factory defaults

> N

Initialize the network

> R

reboot the unit

> S

save the configuration

> T

set date and time

> Z

zero the reset error and powerfail counters

Several of the network directives are intended for internal use only, as
indicated in the detailed descriptions which follow. They have been included
here for completeness.

< D – Show Unit Display

Is used to request what is currently on the display of the workstation
addressed. In the example below, it is the status line.

Directive: < D
Response: 0808001600ND D 8-8 Ready ––Online [M] ? 45

< E – Show Last Error Message

Requests the text of the last error message issued from the language
interpreter at the workstation addressed.

Directive: < E
Response: 0808001600ND E ERROR 03 UNKNOWN AT 255.00.00
TIME OF ERROR ... 1742478802056

< R – Show Last Reset Message

Request the text of the last ‘reset’ error message. If a recoverable “reset”
condition occurs, this message is automatically generated. The < R directive
can then be used to see it again.