Configuring the scanner, Scanner default settings – Rockwell Automation 2755 2D Hand-Held Scanner User Manual
Page 49

4–2
Configuring the Scanner
Publication 2755-6.4
Configuring the Scanner
1. Connect the appropriate Synapse cable to the scanner.
2. Apply power to the Synapse cable (if required).
3. Scan the Set Defaults bar code (in the Programming Guide for
2-D Bar Code Scanners) to configure the scanner with default
settings. Table 4.A lists the scanner default settings.
4. Scan individual bar codes (in the Programming Guide for 2-D
Bar Code Scanners) for parameters you want to change.
5. Scan the communication bar codes for the Synapse cable.
Scanner Default Settings
Table 4.A
Scanner Default Settings
Configuration Parameters
Default Setting
Programming
Guide Reference
Set Default
Set Defaults
1-1
Symbologies
All Enabled,
except
I 2 of 5, and
Codabar
1-3
Code 39 Options
Code 39 Full ASCII
Enabled
1-6
Code 39 Check Digit
Disabled
1-6
UPC/EAN Options
Transmit UPC-A Check Digit
Enabled
1-7
Transmit UPC-E Check Digit
Enabled
1-7
Convert UPC-E to UPC-A
Disabled
1-7
Decode UPC / EAN Supplemental
Disabled
1-8
Convert EAN-8 to EAN-13
Disabled
1-8
UPC-A Preamble
System
Character
1-9
UPC-E Preamble
System
Character
1-9