Communication Setup (Synapse Cable)

5–7

Publication 2755-6.4

Beep on BEL

When enabled, the scanner will beep when a <BEL> character is
detected on the RS-232 link. <BEL> may be used to indicate an
event such as an illegal entry.

Unknown Characters

Unknown characters are characters not recognized by the scanner.
When Send Bar Codes with Unknown Characters is enabled, all
decoded bar code data is transmitted except for the unknown
characters. If this option is disabled, bar codes containing one or
more unknown characters are not transmitted.

Response Timeout

The response timeout determines the maximum amount of time the
scanner will wait before it assumes the end of a transmission. The
timeout period may be from 0.0 to 9.9 seconds in 0.1 second
increments. The default is 2.0 seconds.

To enter a new timeout, scan the timeout label followed by the two
digit timeout. The decimal point is fixed between the first and
second digits.