Troubleshooting and Maintenace

6–3

Publication 2755-6.4

Problem

Probable Cause(s)

Corrective Action

Scan Beam Present,
Symbols Not Read

1. Scanner not set to decode

symbol type scanned.

2. Scanner not held at slight

angle to symbol.

3. Scan beam not crossing

entire symbol.

4. Poor quality bar code

symbols.

5. Loose cable connections.

6. Incorrect interface cable.

1. Verify the scanner decoder

settings.

2. Hold scanner at an angle

to the symbol.

3. Make sure scan beam

crosses every bar and
space on the symbol.

4. Use the symbols provided

on the inside back cover
for testing.

5. Check for loose cable

connections.

6. Check that you are using

the proper cable.

Data is decoded but not
transmitted to host.

1. Scanner is not configured

for the proper cable.

2. Loose connections

3. Scanner communication

settings do not match host
requirements.

1. Make sure the scanner is

configured for the correct
cable (standard RS-232 or
smart cable).

2. Check all cable

connections.

3. Verify cable

communication settings
such as baud rate.