Upc / ean options – Rockwell Automation 2755 2D Hand-Held Scanner User Manual

Page 53

Advertising
background image

4–6

Configuring the Scanner

Publication 2755-6.4

UPC / EAN Options

The section defines options available for UPC-A and UPC-E codes.

Transmit UPC-A Check Digit

When enabled, UPC-A symbol data is transmitted with the check
digit. Enabled is the default.

Transmit UPC-E Check Digit

When enabled, UPC-E symbol data is transmitted with the check
digit. Enabled is the default.

Convert UPC-E to UPC-A

When enabled, this option converts UPC-E (zero suppressed)
decoded data to a UPC-A format before transmission. After
conversion, the output data follows UPC format and follows UPC-A
programming selections (e.g., preamble, check digit). Disabled is
the default.

Decode UPC / EAN Supplemental

The options for decoding UPC/EAN supplemental digits are:

Enabled – supplemental digits are decoded (2 or 5 according to
specific code format conventions, e.g., UPC A+2, UPC E+2,
EAN 8+2). Only symbols with supplemental digits are decoded.

Disabled – supplemental digits are ignored even if present.
Disabled is the default.

Autodiscriminate codes with and without supplemental digits
are decoded.

To minimize the risk of invalid data transmission, we recommend
that you select whether to read or ignore supplemental characters.

Advertising