Control and Configuration Software V6.1

3.8

Printing a Configuration

You can send a copy of the open configuration to a printer or to a text file. The printout
lists the configuration parameters and their assigned values.

To print a configuration:

From the File menu, choose Print, or click

.

The standard Windows Print dialog box. The Selection and Pages options are always
grayed (non-selectable)

Figures 3.8 shows a sample printout.

Figure 3.8 – Sample Configuration File Printout

Drive type: GV3000 V4.0
Configuration: UNTITLED - V/Hz
Prm Value Units Description
P.001 20.0 Sec Accel time 1 (RAMP 1)
P.002: 20.0 Sec Decel time 1 (RAMP 1)
P.003: 5.0 Hertz Minimum speed
P.004: 60.0 Hertz Maximum speed
P.005: 100 % Current limit
P.007: 0 TB digital inputs config
P.008: Analog TB speed ref sel
P.009: 0 TB analog input offset
P.010: 1.000 TB analog input gain
P.011: Off TB analog input invert
P.012: SpdBi TB analog output source
P.013: Fault Output relay config
P.014: None Trim ref. source select
P.015: 0.0 % Trim gain percentage
P.016: 0.0 % Draw gain percentage
P.017: 20.0 Sec Accel time 2 (RAMP 2)
P.018: 20.0 Sec Decel time 2 (RAMP 2)
P.019: On S-Curve Enable
P.020: 5.0 Hertz Jog speed reference
P.021: 20.0 Sec Jog ramp accel time
P.022: 20.0 Sec Jog ramp decel time
P.023: 20.0 Sec MOP accel/decel time
P.024: IET MOP reset configuration
P.025: COAST Stop mode
P.026: IET Func loss type mode
P.027: Off Reverse disable
P.028: 1800 RPM display scaling
P.029: 0 Elapsed time meter
P.030: Off Reverse disable
P.031: 5.0 Hertz Multispeed preset 1
P.032: 5.0 Hertz Multispeed preset 2
P.033: 5.0 Hertz Multispeed preset 3
P.034: 5.0 Hertz Multispeed preset 4
P.035: 5.0 Hertz Multispeed preset 5
P.036: 5.0 Hertz Multispeed preset 6
P.037: 5.0 Hertz Multispeed preset 7
P.038: 5.0 Hertz Multispeed preset 8
P.040: On Motor overload enable
P.041: FrcCool Motor overload type
P.042: 5.0 Sec Line dip ride thru time
P.043: 0 Fault auto reset counts
P.044: 8 Sec Fault auto reset time
P.047: 8 kHz Carrier frequency (kHz)
P.048: V/HZ Controller type select
P.049: USA Country default select
P.060: 1 Network drop number
P.061: Basic Network connection type
P.062: IET Option: comm loss select
P.063: Direct Option: ref source select
P.065: 0.000 Option: type and version
P.095 0.0 Amps Power module output amps
P.098 0.00 Software version number
P.099 UnSel Power module type