Downloading a Configuration to the Drive

You can copy the opened configuration currently in the CS3000 software to the
connected drive.

Important: If FlexPak 3000 parameter changes are disabled by the drive’s Program

Protection jumper (J16), you cannot write parameters to the drive.

To download an opened configuration to the connected drive, follow these steps:

Step 1. Make sure the personal computer is connected to the drive. Refer to sections

2.3 and 3.1 if you need instructions for connecting the personal computer to a
drive.

Step 2. Make sure the drive is stopped before downloading a configuration to the

drive.

Step 3. From the Config menu, choose Download, or click

.

Step 4. If the downloaded configuration contains parameter values that are out of

range for the drive, the software on the drive modifies these parameter
values to bring them within allowed ranges. If this occurs, a Download
Configuration Changed dialog box is displayed. This dialog box displays the
differences between the downloaded configuration and the configuration
currently in the drive. The software prompts you to specify if the changes
made in the drive should also be made to the configuration in the CS3000
software. To update the opened configuration, select Yes. To not update the
configuration, select No.

!

ATTENTION: The download command replaces the parameter values in
the drive with the parameter values from the open configuration. Only
qualified personnel should develop and download drive configurations.
Read and understand the drive instruction manual in its entirety before
downloading a configuration. Failure to observe this precaution could
result in severe bodily injury or loss of life.