8-4

Control and Configuration Software V6.1

8.4

Selecting the Control Source

The following note applies to GV3000 and Liqui-Flo AC drives only.

You can select one of the following as the control source for the drive:

Local

Terminal Strip

Serial

Network

You must select Serial to control the drive by using the Drive Control window. If any
other control source is selected, you can only monitor the drive functions displayed in
the Drive Metering window and stop the drive by using Stop/Reset; all of the other
drive commands on the Drive Control screen are disabled.

8.5

Selecting the Reference Mode (Auto/Manual)

The Reference Mode control is active only if the control source is set to Serial
(CS3000 software control). Use the Auto/Man button to switch the drive reference
mode for the connected drive between auto mode and manual mode.

8.6

Selecting the Direction of Motor Rotation

The direction control is active only if the control source is set to Serial (CS3000
software control). The Fwd/Rev button toggles between Forward and Reverse. When
you make a selection, the appropriate command (forward or reverse) is sent to the
drive.

8.7

Setting the Drive Reference

The Manual Reference group box lets you set the drive reference.

!

ATTENTION: When parameter P.055 is set to ON, the STOP/RESET key
is functional only from the selected control source. As a safety precaution,
Reliance Electric recommends that an emergency stop push button be
located near the drive in an easily accessible location. As a further safety
precaution, the user should post a warning on the drive to alert personnel
that the STOP/RESET key is not functional. Failure to observe this
precaution could result in severe bodily injury or loss of life.

To use references from the:

Choose:

Set Reference dialog box within the Drive Control
window

Manual mode

selected terminal strip source

Auto mode

Advertising