Add-on instruction parameters – Rockwell Automation RSLogix 5000 Fuzzy Designer User Manual

Page 135

Advertising
background image

Publication LOGIX-UM004A-EN-P - March 2007

RSLogix 5000 Add-On Instruction 135

In RSLogix 5000 software, the Add-On Instruction names are stored in
the same namespace as all other built-in instructions and data types
(system or user-defined). Therefore, the Add-On Instruction name
must be unique. Otherwise, an error message will appear during the
import of the fuzzy Add-On Instruction. When exporting the fuzzy
Add-On Instruction, you can select the folder to which you want to
save the L5X file. You can also enter these optional parameters:

• Add-On Instruction Major Revision
• Minor Revision
• Vendor
• Revision Note.

Add-On Instruction Parameters

The Add-On Instruction parameters correspond to the fuzzy system
input and output ports. The ordering of parameters follows the order
of the ports. Port order is determined, by default, by the order in
which the ports are added to the project. The port order can also be
set from the Tools > Set Port Order menu item. The following
parameter attributes are set to default values:

• Name – The name of parameters are the same as the names of

fuzzy system input and output ports.

• Usage – The usage is set to Input (for input ports) or Output (for

output ports).

• DataType – The DataType of all input and output parameters is set to

REAL.

• Required – The attribute Required is set to true, that is, the

attribute requires an argument.

• Visible – The attribute Visible is set to true, that is, the attribute

is visible on the RLL and FBD Instruction face when the AOI is
invoked.

• Description – The description is taken from the Description field

on the Project Information dialog (Project > Project Information
menu item).

• Description of input and output parameters – The description is

taken from the Description tab on the Input or Output Port
properties dialog.