Rockwell Automation RSLogix 5000 Fuzzy Designer User Manual

Page 81

Advertising
background image

Publication LOGIX-UM004A-EN-P - March 2007

FuzzyDesigner Projects 81

Rescale Membership Functions of the Applied Terms – Click

this check box to rescale the membership functions of all
terms of the ILV.

• Terms tab dialog – The ILV properties dialog defines the variable

through the following terms.

Input Linguistic Variable Properties Dialog – Terms Tab Dialog

Count – Specify number of terms, fuzzy sets, related to the

variable.

Type – Select either the trapezoid or s-function ILV term type.

When the ILV properties dialog is open for the existing
variable, the term type of the applied variable terms is
displayed. Other is displayed when term types for the
selected variable differ.

Names – Select default names of terms for the variable. When

the ILV properties dialog is open for the existing variable, any
applied terms are shown.

IMPORTANT

The minimum value must be always lower then the maximum
value. When the dialog for a new ILV is opened the default
range is preset to –1 for minimum and 1 for maximum.

IMPORTANT

When the ILV properties dialog is open for an existing variable,
then the terms count, the type and the names are visible, but
you cannot change them in the properties dialog.