3. In the FactoryTalk Directory Server Configuration dialog box, click This computer,

and then click OK.

To change the Network Directory location, you have to log on as an administrator on
the new Network Directory computer (local or remote).

4. Click OK, and then restart the client computer.

Install FactoryTalk View SE

1. Close all open Windows programs.

2. Place the FactoryTalk View Installation DVD in the computer’s DVD drive.

If the DVD does not start automatically, run D:\Setup.exe, where D: is the drive
containing the DVD.

3. Select Site Edition Client and click Next.

Install any necessary product updates

For instructions, see “Installing product updates” on page 132.

Specify Server #2 as the Network Directory location

After upgrading the software on the client computer, specify Server #2 as the Network
Directory location.

1. On the client computer, click Start > All Programs > Rockwell Software >

FactoryTalk Tools, and then click Specify FactoryTalk Directory Location.

To use the FactoryTalk Directory Server Location Utility, you have to log on as an
administrator on the local computer.

2. Localhost should be displayed in the field, Computer hosting directory server. Click

the Browse button.

3. In the FactoryTalk Directory Server Configuration dialog box, type Server #2, and

then click OK.

To change the Network Directory location, you have to log on as an administrator on
the new Network Directory computer (local or remote).

4. Click OK, and then restart the client computer.