7. Select or clear the checkbox Encrypt File Contents. If you decide to encrypt file

contents, you must enter and confirm a passphrase. Then click OK.

Ensure that the FactoryTalk Network Directory is set up

On the computer that will host the FactoryTalk Network Directory, ensure that the
FactoryTalk Services Platform is installed, and that localhost is specified as the Network
Directory location.

To specify localhost as the Network Directory location

1. On the Network Directory computer, click Start > All Programs > Rockwell

Software > FactoryTalk Tools, and then click Specify FactoryTalk Directory
Location
.

To use the utility, you have to log on as a local administrator.

2. If localhost is displayed in the field, Computer hosting directory server, the computer

is already specified as the Network Directory host. You can close the utility.

If localhost is not displayed, click the Browse button.

3. In the FactoryTalk Directory Server Configuration dialog box, click This computer,

and then click OK.

4. Click OK again, to close the FactoryTalk Directory Server Location Utility.

Move the application’s HMI project files

Use the HMI Server Backup and Restore utility to back up HMI project files that belong
to HMI servers in the application you are deploying.

To run the HMI Server Backup and Restore utility, click Start > All Programs >
Rockwell Software > FactoryTalk View > Tools > HMI Server Backup and
Restore
. For details about using the utility, click the Help button.