Drive Ratings
DC
Motor
Motor
Rated
DC
Armature
Field
Field
Motor
AC Line
Input
Armature Current
Voltage Current
HP
Amps
KVA
Voltage
(Amps)
(Amps)
1/4
4.5
0.5
90
2.7
50
1
4.5
0.5
90
2.7
100
1
1/3
5.9
0.7
90
3.5
50
1
5.9
0.7
90
3.5
100
1
1/2
7.8
0.9
90
5
50
1
3.7
0.8
180
2.5
100
1
3.7
0.8
180
2.5
200
1
3/4
10.6
1.2
90
7.6
50
1
5.6
1.3
180
3.8
100
1
5.6
1.3
180
3.8
200
1
1
13
1.5
90
10
50
1
7
1.6
180
5
100
1
7
1.6
180
5
200
1
1.5
--
--
--
--
--
--
10.1
2.3
180
7
100
1
10.1
2.3
180
7
200
1
2
--
--
--
--
--
--
12
2.8
180
9.2
100
1
12
2.8
180
9.2
200
1
Efficiency (at maximum horsepower output)
92%
3