Rockwell Automation DC3E Non-Regenerative DC Drive User Guide 1/4 - 2 HP, 115/230 VAC User Manual

Page 11

Advertising
background image

Drive Ratings

DC

Motor

Motor

Rated

DC

Armature

Field

Field

Motor

AC Line

Input

Armature Current

Voltage Current

HP

Amps

KVA

Voltage

(Amps)

(Amps)

1/4

4.5

0.5

90

2.7

50

1

4.5

0.5

90

2.7

100

1

1/3

5.9

0.7

90

3.5

50

1

5.9

0.7

90

3.5

100

1

1/2

7.8

0.9

90

5

50

1

3.7

0.8

180

2.5

100

1

3.7

0.8

180

2.5

200

1

3/4

10.6

1.2

90

7.6

50

1

5.6

1.3

180

3.8

100

1

5.6

1.3

180

3.8

200

1

1

13

1.5

90

10

50

1

7

1.6

180

5

100

1

7

1.6

180

5

200

1

1.5

--

--

--

--

--

--

10.1

2.3

180

7

100

1

10.1

2.3

180

7

200

1

2

--

--

--

--

--

--

12

2.8

180

9.2

100

1

12

2.8

180

9.2

200

1

Efficiency (at maximum horsepower output)

92%

3

Specifications

250-0287-rev2.qxd

3/12/01

10:27 AM

Page 3

Advertising