Rockwell Automation DC3E Non-Regenerative DC Drive User Guide 1/4 - 2 HP, 115/230 VAC User Manual
Page 52
Advertising
![background image](/manuals/581714/52/background.png)
44
Operation
Figure 11. Dynamic Brake Connection
DC3N DRIVE
Table 4. Minimum Recommended Dynamic Brake
Resistor Values
Motor Armature
Minimum
Minimum
Current Rating
Dynamic Brake
Dynamic Brake
Wattage
Resistor Value
Resistor
Less than 2 ADC
1 ohm
1W
2–3 ADC
5 ohm
5W
3–5 ADC
10 ohm
20W
5–10 ADC
20 ohm
40W