13
Installation
Line fusing
This DC3 drive model has 15-amp line fuses preinstalled
on fuse holders 501 and 502 (FU501 and FU502). When
replacing the line fuses, use fast acting fuses rated for 250
VAC or higher. See Figure 3, page 6, for fuse holder
location, and Table 1 for recommended replacement line
fuse sizes for specific application ratings.
Table 1. Recommended Line Fuse Sizes
90 VDC Motor
180 VDC Motor
Max. DC Armature
AC Line Fuse
Horsepower
Horsepower
Current (amps)
Size (amps)
1/20
1/10
0.5
3
1/15
1/8
0.8
3
1/8
1/4
1.5
5
1/6
1/3
1.7
5
1/4
1/2
2.6
8
1/3
3/4
3.5
8
1/2
1
5.0
10
3/4
1 1/2
7.6
15
1
2
10
15
Reliance Electric offers a 0.5A pico fuse (part number 050-
–0074) which protects the control board power supply
transformer and logic.
250-0287-rev2.qxd
3/12/01
10:27 AM
Page 13
Advertising