Specifications – Rockwell Automation DC3E Non-Regenerative DC Drive User Guide 1/4 - 2 HP, 115/230 VAC User Manual

Page 9

Advertising
background image

Specifications

Max.

Armature

HP Range

HP Range

Current

with115 VAC

with 230 VAC

Model

(Amps DC)

Applied

Applied

DC3N-12D-00-010-AI

10A

1/4 – 1

1/2 – 2

DC3N-12D-4X-010-AI

10A

1/4 – 1

1/2 – 2

Model

Style

DC3N-12D-00-010-AI

Open chassis

DC3N-12D-4X-010-AI

NEMA 4X/12

AC Line Voltage

115 VAC or 230 V AC, 50 or 60 Hz, 1 Phase

Maximum Allowable Symmetrical AC Line Current

5000 amps

Maximum AC Line Distribution kVA

with 115 VAC Input

25 kVA

with 230 VAC Input

50 kVA

Armature Voltage

With 115 VAC Input

0 – 90 VDC

With 230 VAC Input

0 – 180 VDC

Field Voltage

115 VAC Input

50 VDC (F1 to L1); 100 VDC (F1 to F2)

230 VAC Input

100 VDC (F1 to L1); 200 VDC (F1 to F2)

Maximum Field Current

1 ADC

Adjustments and Application Data

Form Factor

1.37 at base speed

Service Factor

1

Maximum Speed Trimpot Range (% of rated voltage)

0 to 90%

1

250-0287-rev2.qxd

3/12/01

10:27 AM

Page 1