38

Operation

Drive operation

Chassis drive operation

POWER ON start

SPEED REFERENCE: External signal or
potentiometer
START/STOP control: POWER ON/OFF

IMPORTANT:

It is necessary to wire a jumper between

B1 and B3 if no START/STOP switches are to be used.

IMPORTANT:

Line starting and line stopping (applying

and removing AC line voltage) is recommended for
infrequent starting and stopping of a drive only. When AC
line voltage is applied to the drive, the motor accelerates to
the speed set by the speed adjust potentiometer or analog
input signal. When AC line voltage is removed, the motor
coasts to a stop.

1.

Turn the speed adjust potentiometer full
counterclockwise (CCW), or set the external reference
signal so that it is at its lowest level (0V or 4 mA).

2.

Apply AC line voltage.