The chassis units do not have to be earth grounded. If you
choose to ground the chassis, use a star washer beneath the
head of at least one of the mounting screws to penetrate the
anodized chassis surface and to reach bare metal.

Isolation transformer

11

Installation

ATTENTION:

Distribution system capacity above the

maximum recommended system KVA requires the use
of an isolation transformer, a line reactor, or other
means of adding similar impedance to the drive power
input. Failure to observe these precautions could result
in damage to, or destruction of, the equipment

ƽ

Input isolation transformers might be needed to help
eliminate the following:

·

Damaging line voltage transients from reaching the

drive.

·

Line noise from the drive back to the incoming power

source.

·

Damaging currents that could develop if a point inside

the drive becomes grounded.