Section 2torch: introduction, 2t.01 scope of manual, 2t.02 specifications – Tweco 42 CutMaster Service Manual User Manual

Page 19: Introduction cutmaster 42

Advertising
background image

INTRODUCTION CUTMASTER 42

Manual 0-5171 2T-1 Introduction

SECTION 2TORCH:

INTRODUCTION

2T.01 Scope of Manual

This manual contains descriptions, operating instruc-

tions and maintenance procedures for the SL40 Plasma

Cutting Torch. Service of this equipment is restricted

to properly trained personnel; unqualified personnel are

strictly cautioned against attempting repairs or adjust-

ments not covered in this manual, at the risk of voiding

the Warranty. Read this manual thoroughly. A complete

understanding of the characteristics and capabilities of

this equipment will assure the dependable operation for

which it was designed.

2T.02 Specifications

A. Torch Configurations

1. Hand Torch, Model SL40

The hand torch head is at 75° to the torch handle.

The hand torches include a torch handle and torch

trigger assembly.

8.3" (210.82mm)

2.6"

(66.04mm)

.96" (24.38mm)

Art # A-09336

B. Torch Leads Lengths

Hand Torches are available as follows:

• 15 ft / 4.6 m.

C. Torch Parts

Starter Cartridge, Electrode, Tip, Shield Cup

D. Parts - In - Place (PIP)

Torch has built-in switch.

12 vdc circuit rating

E. Type Cooling

Combination of ambient air and gas stream through

torch.

F. Torch Ratings

SL40 Torch Ratings

Ambient

Temperature

104° F

40° C

Duty Cycle

100% @ 40 Amps @ 193 scfh

Maximum Current

40 Amps

Voltage (V

peak

)

500V

Arc Striking Voltage

500V

Torch Control Circuit

Voltage

24V

G. Current Ratings

SL40 Current Ratings

SL40 Torch & Leads

Up to 40 Amps, DC,

Straight Polarity

NOTE

Power Supply characteristics will determine

material thickness range.

H. Gas Requirements

SL40 Torch Gas Specifications

Gas (Plasma and Secondary)

Compressed Air

Minimum Input Pressure

85 psi

5.9 bar

Maximum Input Pressure

125 psi / 8.6 bar

Gas Flow

193 scfh

91 lpm

!

WARNING

This torch is not to be used with oxygen (O

2

).

This torch is not to be use with high frequency

starting systems.