Troubleshooting 6-16 Manual 0-5171

CUTMASTER 42

TROUBLESHOOTING

6.15 Waveforms

1. Vds of inverter IGBT at no load

Test point C1: 4 and 5 C2: 9 and 10 (Testpoints refer to inverter PCB diagram in Sec. 6.13).

Timebase

Trigger

Stop

Positive

Art # A-10247

2. Vds of inverter IGBT at full load
Test point C1: 4 and 5 C2: 9 and 10 (Testpoints refer to inverter PCB diagram in Sec. 6.13 ).

Timebase

Trigger

Stop

Positive

Art # A-10248

6.16 Main Circuit Description

!

Turn off power and disconnect mains supply plug from receptacle before working on the unit. Allow two minutes for

capacitors to discharge after disconnection from mains supply voltage.

PFC Control Chip

AC

AC

V+

V-

U1

DC+

DC-

DC+

DC-

dc+

dc+

Art # A-10249