Troubleshooting 6-8 Manual 0-5171

CUTMASTER 42

TROUBLESHOOTING

IGBT Testing

Multimeter Lead Placement

Diode Voltage

IGBT 1

Positive meter lead to test point 3

0.2000 to 0.8000 VDC

Negative meter lead to test point 2

IGBT 2

Positive meter lead to test point 5

0.2000 to 0.8000 VDC

Negative meter lead to test point 4

IGBT 3

Positive meter lead to test point 8

0.2000 to 0.8000 VDC

Negative meter lead to test point 7

VIGBT 4

Positive meter lead to test point 10

0.2000 to 0.8000 VDC

Negative meter lead to test point 9

PFC IGBT 1

Positive meter lead to test point 14

0.2000 to 0.8000 VDC

Negative meter lead to test point 13

PFC IGBT2

Positive meter lead to test point 12

0.2000 to 0.8000 VDC

Negative meter lead to test point 11

PILOT IGBT1

Positive meter lead to test point 26

0.2000 to 0.8000 VDC

Negative meter lead to test point 25

Table 6-2 IGBT’s, Multimeter set to measure Diode Voltage

6.09 Check Main On / Off Switch

!

Read and follow safety information in Section 6.02 before proceeding.

Art # A-10245

1

2

3

4

Power Switch Testing

Multimeter Lead Placement

Impedance

Switch ON

Positive meter lead to testpoint 1

Negative meter lead to testpoint 2

0 to 1 Ω

Switch ON

Positive meter lead to testpoint 3

Negative meter lead to testpoint 4

0 to 1 Ω

Switch OFF

Positive meter lead to testpoint 1

Negative meter lead to testpoint 2

> 1k Ω

Switch OFF

Positive meter lead to testpoint 3

Negative meter lead to testpoint 4

> 1k Ω

Table 6-3 Power Switch, Multimeter set to measure ohms (Ω)