4.03 Sequence of Operation

The following is a typical sequence of operation for this power supply.

1. Place the ON / OFF switch on the power supply to ON (up) position (Red indicator lamp is illuminated).

a. AC indicator

turns on; fan turns on.

NOTE

During initial power up, there will be a delay of about 2 seconds before the AC Indicator light will illuminate

and the pre-flow gas and fan starts. The gas will automatically flow from torch for approximately 10 seconds

(only after the AC Indicator lamp is illuminated) (The AC Indicator lamp and fan turns on approximately 2

seconds after the ON/OFF switch is enabled), this is a process that makes sure all inputs (gas, input power,

torch connection, and torch parts) are acknowledged for proper operation.

2. Wear protective clothing, including welding gloves and appropriate eye protection (see table 1-1). Place tip on

work piece and pull trigger. Arc will initiate and start cutting material.