OPERATION CUTMASTER 42

Manual 0-5171

4-1 Operation

SECTION 4 SYSTEM:

OPERATION

4.01 Control Panel

Art# A-09338-AD

CUTMASTER

®

42

AC Indicator

The Front Panel

The Rear Panel

Overheat Indicator

Air Indicator

DC Indicator (Ready)

Air Inlet

On/Off

Switch

Power Cord

A

120V 15A

120V 20A

230V 20A

24

40

20

20

30

27

1. ON / OFF Switch (Power Switch/Lamp)

Controls input power to the power supply. I is ON (Red Lamp), O is OFF.

2. (A) Output Current Control

Sets the desired output current. If the overload protection (fuse or circuit breaker) on the input power circuit

opens frequently, either reduce cutting output, reduce the cutting time, or connect the unit to more adequate

input power. Note: For 120V input power, the unit will automatically limit the output current to a maximum of

27A. For 230V input power, the maximum output is 40 Amps. Refer to Section 2 for input power requirements.

3.

AC Indicator

Steady light indicates power supply is ready for operation.

4. OVERHEAT Indicator (TEMP Indicator)

Indicator is normally OFF. Indicator is ON when internal temperature exceeds normal limits. Allow the unit to

run with the fan on until the temp indicator turns off.

5.

AIR Indicator

AIR light should be ON when there is sufficient gas pressure.

6. READY (DC Indicator)

Indicator is ON when DC output circuit is active.