Troubleshooting 6-6 Manual 0-5171

CUTMASTER 42

TROUBLESHOOTING

6.06 Visually Inspect

Visually inspect the inside of the Power Source. The levels of current present in these units can cause burning or arcing

of PCB, transformers, switches, or rectifier when a failure occurs. Carefully inspect all components within these units.
Look in particular for the following:
a) Loose or broken wires or connectors.
b) Burned or scorched parts or wires or evidence of arcing.
c) Any accumulation of metal dust or filings that may have caused shorting or arcing.
If any parts are damaged, they must be replaced. Refer to the Spare Parts section for a complete list of components

used in the Power Source.
Locate the faulty component(s) then replace where necessary.

6.07 Preliminary DC Bus Measurement of the Main Inverter Board

!

Read and follow safety information in Section 6.02 before proceeding.

DC Bus Testing

Multimeter Lead Placement

Voltage with Supply voltage OFF

Upper capacitor bank

Positive meter lead to testpoint 30

Negative meter lead to testpoint 29

0 VDC

Lower capacitor bank

Positive meter lead to testpoint 32

Negative meter lead to testpoint 31

0 VDC

Table 6-1 DC BUS, Multimeter set to measure DC volts