04 air supply connections, Installation cutmaster 42 – Tweco 42 CutMaster Service Manual User Manual

Page 23

Advertising
background image

INSTALLATION CUTMASTER 42

Manual 0-5171

3-3 Installation

3.04 Air Supply Connections

A. Connecting Air Supply to Unit
The connection is the same for compressed air or industrial compressed air in gas cylinders.
1. Connect the gas line to the compressed air inlet port at the appropriate pressure.

Art# A-09337

Air Inlet

On/Off

Switch

Figure 3-2 Gas Connection to Compressed Air input

B. Using Industrial Compressed Air In Gas Cylinders
When using Industrial compressed air in gas cylinders as the gas supply:
1. Refer to the manufacturer’s specifications for installation and maintenance procedures for high pressure gas

regulators.

2. Examine the cylinder valves to be sure they are clean and free of oil, grease or any foreign material. Briefly open

each cylinder valve to blow out any dust which may be present.

3. The cylinder must be equipped with an adjustable high - pressure regulator capable of outlet pressures up to 100

psi (6.9 bar) maximum and flows of at least 250 scfh (120 lpm).

4. Connect gas supply hose to the cylinder.

NOTE

Pressure should be set at 100 psi (6.9 bar) at the high pressure gas cylinder regulator.
Supply hose must be at least 1/4 inch (6 mm) I.D.
For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's instructions. Do

Not use Teflon tape as a thread sealer, as small particles of the tape may break off and block the small gas

passages in the torch.