02 preparations for operating, Cutmaster 42 operation – Tweco 42 CutMaster Service Manual User Manual

Page 28

Advertising
background image

CUTMASTER 42 OPERATION

Operation 4-2 Manual 0-5171

NOTE

All consumables must be correctly installed and maintained to ensure correct operation.

4.02 Preparations For Operating

At the start of each operating session:

WARNING

Disconnect primary power at the source before assembling or disassembling power supply, torch parts,

or torch and leads assemblies.

A. Torch Parts Selection

Check the torch for proper assembly and appropriate torch parts. The torch parts must correspond with the type

of operation, and with the amperage output of this power supply (40 amps maximum). Use only genuine Thermal

Dynamics parts with this torch.

Art # A-09340-AG

Start Cartridge,
Cat. No. 9-0097

Electrode, Cat. No. 9-0096

Worn Electrode

Worn Tip

40 Amp Drag Tip, Cat. No. 9-0093

Shield Cup, Cat. No. 9-0098

40 Amp
Standoff Tip,
Cat. No. 9-0094

NOTE

When operating the torch in a normal condition, some gas vents through the gap between the shield cup

and torch handle. Do not attempt to over tighten the shield cup as irreparable damage to internal compo-

nents may result.

NOTE

For 115VAC, 20A Drag Cutting Tip ( Cat.No. 9-0091) shall be used (refer to 9.03 SL40 Replacement Parts).